Place of Origin : China/Japan

Brand Name : Mistubishi

Model Number : FX3U-16MT/ES-A, FX3U-16MT/ES-A

Packaging Details : Carton packaging

Supply Ability : 10pc/per week

Price : $50-$500

MOQ : 1/pc

Payment Terms : T/T, western union

Delivery Time : Within 3 Working Days

Shipping by : DHL,UPS,Fedex and EMS

Package : professional anti-static bag

Warranty : 1 year

Quality : 100% Original Made

Payment term : T.T WESTUNION

Port : Guangdong, Dongguan, Shenzhen or as your selection

Contact Now

Industrial Automation Products Mistubishi Programmable Logic Controllers FX3U-16MT/ES-A Automate

The FX3U series base units are available with 16, 32, 48, 64, 80 or 128 input/output points expandable to 384 points.
It is possible to choose between relay and transistor output type.

Mitsubishi FX3U Series PLC Special Features:

  • Integrated serialinterfacefor communication between PCsandHMI

  • Integrated positioning control

  • Exchangeable interface modules for direct mounting into a base unit

  • LEDs for indicating the input and output status

  • Slot for memory cassettes

  • Integrated real-time clock

  • Expandable with digital I/O modules, special function modules and ADP modules

  • User-friendly programming systems, including IEC 1131.3 (EN 61131.3) compatible programming software, HMIs and hand-held programming units

Ambient temperature 0-55 ° C: During operation, -25-75 ° C: During storage
Relative humidity 5 to 95% RH (no condensation) ・ ・ ・ ・ ・ ・ During operation
Vibration resistant When mounting the DIN rail Frequency: 10-57Hz One-sided amplitude: 0.035mm X, Y, Z 10 times in each direction (80 minutes in total) Judgment criteria are based on IEC 61131-2
Frequency: 57-150Hz Acceleration: 4.9m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) Judgment criteria are based on IEC 61131-2
At the time of direct mounting Frequency: 10-57Hz One-sided amplitude: 0.075mm X, Y, Z 10 times in each direction (80 minutes in total) Judgment criteria are based on IEC 61131-2
Frequency: 57-150Hz Acceleration: 9.8m / s 2 X, Y, Z 10 times in each direction (80 minutes in total) Judgment criteria are based on IEC 61131-2
Impact resistance 147m / s 2 , action time 11ms, sine and cosine half-wave pulse 3 times in each direction of X, Y, Z Judgment criteria are based on IEC61131-2
Noise resistance Based on a noise simulator with a noise voltage of 1,000 Vp-p, a noise width of 1 μs, a rise of 1 ns, and a period of 30 to 100 Hz.
Withstand voltage When conducting a withstand voltage test, use the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: AC1.5kV 1 minute DC24V service power supply, and between input terminal (DC24V) and ground terminal: AC500V 1 minute Between output terminal (transistor) and ground terminal: AC500V 1 minute
Insulation resistance When conducting an insulation resistance test, use the following voltage between each terminal and the ground terminal of the basic unit. Between power supply terminal (AC power supply) and ground terminal: 5MΩ or more with DC500V insulation resistance tester DC24V service power supply, and between input terminal (DC24V) and ground terminal: 5MΩ or more with DC500V insulation resistance tester Output terminal (transistor) and ground terminal Between: 5MΩ or more with DC500V insulation resistance tester
ground Class D grounding (grounding resistance: 100Ω or less) <Common grounding with strong electric system is not possible> Grounding should be dedicated grounding or shared grounding.
Usage atmosphere No corrosive or flammable gas, no terrible conductive dust
Altitude used It cannot be used in an environment where the pressure is 2000 m or less and the atmospheric pressure is higher than the atmospheric pressure. It may break dow



Quality Industrial Automation Products Mistubishi Programmable Logic Controllers FX3U-16MT/ES-A Automate wholesale

Industrial Automation Products Mistubishi Programmable Logic Controllers FX3U-16MT/ES-A Automate Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Changsha Zhinian Automation Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)